Home-Case-Solution of low voltage distribution in data center

Solution of low voltage distribution in data center

The power distribution system of the data center distribues the power supply of the electricity, generator and UPS to the related load safely and reliably. Therefore, the power distribution system of data center should be designed according to the following points:

1, feasibility, distribution system is the complex of receiving and distributing power, its composition is influenced by many factors such as space, temperature, humidity and so on. It is necessary to consider the feasibility of distribution system in distribution system.

2, reliability, power supply reliability refers to the reliability of the power supply system uninterrupted power supply. The different reliability should be guaranteed according to the load level. In design, double accidents are not considered.

3. Safety and flexibility. The line of power supply system should ensure that operation and maintenance are convenient, and operation and maintenance are safe and reliable during normal operation and accident. To this end, we should simplify the line, reduce the level of power supply and operation procedures.

4, economy, the distribution scheme should be simple to meet the requirements of production and guarantee the quality of power supply, so as to reduce the cost of investment and operation, and to improve the safety of power supply.

5, forward-looking, the power distribution plan should ensure that it is easy to develop in the future, and at the same time, it can meet the needs of phased construction.

Based on the characteristics of the distribution system of data center and the experience of accumulating in the data center for many years, a complete set of data center distribution equipment is designed to meet the demand of all the electrical equipment used in the data center. It covers the front end receiving unit, the middle end feeding unit and the terminal power distribution unit.

Main power receiving ATS cabinet: power distribution cabinet for main power supply and dual power conversion

1, the rated current 63A~2000A is optional.

2, city power generation conversion cabinet

3. Emergency lighting control cabinet

Power distribution cabinets: distribution cabinets used for distribution power

1. The rated current 63A~630A is optional

2. Lighting distribution cabinet

3, fan, pump control cabinet

4, precision air conditioning distribution cabinet

5. Other load distribution cabinets

UPS input distribution cabinet: distribution of power supply or power source to UPS cabinet.

UPS output switchgear: distribution cabinet from UPS feeder circuit to power distribution cabinet with precision head cabinet.

Intelligent precision column cabinet: power distribution cabinet allocated to each server cabinet PDU.

PDU: power supply for each server in the cabinet

Product architecture